BDM-610000082 Rev A Chapter 4: Using the cpuModule 57
Clear Register:
A read to this register Clears the IRQs and a write to this register sets the DIO-Compare, DIO- Mask,
DIO-Control, Port 1, and Port 0 to zeros. A write to this register is used to clear the board.
Port 0 Direction Register:
Writing a zero to a bit in this register makes the corresponding pin of the aDIO connector an input. Writing
a one to a bit in this register makes the corresponding pin of the aDIO connector an output.
Mask Register:
Writing a zero to a bit in this register will not mask off the corresponding bit in the DIO-Compare register.
Writing a one to a bit in this register masks off the corresponding bit in the DIO-Compare register. When all
bits are masked off the aDIOs comparator is disabled. This condition means Event and Match mode will not
generate an interrupt. This register is used by Event and Match modes.
Compare Register:
A Read/Write register used for Match Mode. Bit values in this register that are not masked off are compared
against the value on Port 0. A Match or Event causes bit 6 of DIO-Control to be set and if the aDIO is in
Advanced interrupt mode, the Match or Event causes an interrupt.
Table 37 DIO-Control I/O Address EC3h—Read Access
D7 D6 D5 D4 D3 D2 D1 D0
Table 38 DIO-Control I/O Address EC3h—Write Access
D7 D6 D5 D4 D3 D2 D1 D0
Table 39 Multi-Function at Address EC2h
1
1. Contents based on bits D0 and D1 of DIO-Control.
XXXXXXXX
I/O I/O I/O I/O I/O I/O I/O I/O
M7 M6 M5 M4 M3 M2 M1 M0
C7 C6 C5 C4 C3 C2 C1 C0
Strobe 0 Status
0 = no strobe
1 = strobe
Digital IRQ Status
0 = no digital interrupt
1 = digital interrupt
Strobe 1 Status
0 = no strobe
1 = strobe
Digital IRQ Mode
00 = Disabled
01 = strobe Mode
10 = event mode
11 = match mode
Port 1 Direction
0 = input
1 = output
Multi-Function
Register Select
00 = clear mode
01 = port 0 direction
10 = mask register
11 = compare register
Multi-Function
Register Select
00 = clear mode
01 = port 0 direction
10 = mask register
11 = compare register
Port 1 Direction
0 = input
1 = output
Reserved
read/write 00 clear
0 in, 1 out 01 Port 0 direction
0 no mask, 1 mask 10 DIO mask
read/write 11 compare
Digital IRQ Mode
00 = Disabled
01 = strobe Mode
10 = event mode
11 = match mode