5-14
1. Raster Position
1-1. Horizontal Raster Position Signal: No.36 (H.HOLD 2(130k)) All Black
1) Receive signal 36.
2) Adjust SCREEN-VR on the FBT so that the back raster just appears.
3) Make sure to set the position of control as follows.
VR581: Fully clockwise (MAX).
SW581: Set position to the CRT side.
4) Open Menu (S), TAG2 "H.SIZE", Horizontal Size and adjust "+", "-" SW so that the horizontal size is
396±2.0 mm.
5) If raster has approached on the left of displayed area, change the SW581 position to the CRT side If
raster has approached on the right of displayed area, change the SW581 position to the VR581 side.
6) Adjust VR581 so that the distance between the bezel and raster edge is as follows.
|
XL
eft
-XR
ight
| " 1.0 mm
XLeft
XRight
Bezel
Raster
396
±
2.0mm
Fig 1-1 Horizontal Raster Centering
Page view 42