1 Check if the connector of drawer fits the definition of SENOR standard drawer connector;
2 Check if the 6pin crystal connector becomes oxidized or dirty
3 Check if the 6pin socket becomes oxidized , dirty or out of shape;
4 Check if the fourth drawer connector is under AC 20V;
5 Check if the big cable between the communication board and the mainboard looses or drops;
6 It may be the problem of communication board or circuit abnormalities of mainboard. Please
change a new communication board for testing, if it still doesnt work, change a new mainboard
for testing again.