LI-30
LIGHTING SYSTEM
Room Light
28.Room Light
A: REMOVAL
1) Disconnect the ground cable from battery.
2) Remove the lens (A) and mounting screws (B).
3) Disconnect the harness connector and remove
the room light.
B: INSTALLATION
Install in the reverse order of removal.
C: INSPECTION
1. ROOM LIGHT BULB
1) Visually check the bulb for blow out.
2) Check the bulb specification. <Ref. to LI-2,
SPECIFICATION, General Description.>
3) If NG, replace the bulb with a new one.
2. ROOM LIGHT SWITCH
Measure the resistance between room light switch
terminals.
LI-00315
(A)
LI-00316
(B)
Switch position Terminal No. Standard
OFF — More than 1 MΩ
ON 1 and 3 1.5±0.5 Ω
DOOR 2 and 3 1.5±0.5 Ω