COM-3
COMMUNICATION SYSTEM
Horn System
2. Horn System
A: WIRING DIAGRAM
1. HORN
<Ref. to WI-164, WIRING DIAGRAM, Horn Sys-
tem.>
B: INSPECTION
1. HORN RELAY
Measure the horn relay resistance between termi-
nals (indicated in the table below) when connecting
the terminal No. 4 to battery positive terminal and
terminal No. 3 to battery ground terminal.
Current Terminal No. Standard
Flow
1 and 2
Less than 1 Ω
No Flow More than 1 MΩ
COM00001
(1)
(2)
(1)
(4)
(2)
(3)
(3)
(4)